Mechanical dimensions, Mechanical dimensions -3, Fig. 2-1 a dimension -3 fig. 2-2 b dimension -3 – Hardy ANY-WEIGH Bench Scales User Manual

Page 11: Fig. 3-1 l

Advertising
background image

Chapter 2 - Specifications

2-3

Linearity*

0.11% of full scale

* Some barrier protection is required where the unit
is located in a hazardous area.

Response Time

250 milliseconds

Sensitivity

3 mV/V of full scale with
adjustment to 2 mV/V

Temperature Range

0 to +60° C

Temperature Coefficient

10.025%/° C

Cable

15 Feet

Mechanical
Dimensions

The following dimensions are for reference only:

FIG. 2-1 A DIMENSION

NOTE:

Cable dimension is for the Universal and Analog
scales only. DeviceNet cable length is different, see
DeviceNet Specification above.

FIG. 2-2 B DIMENSION

Six conductor shielded
15 Feet

A

B