2-3
Linearity*
0.11% of full scale
* Some barrier protection is required where the unit
is located in a hazardous area.
Response Time
250 milliseconds
Sensitivity
3 mV/V of full scale with
adjustment to 2 mV/V
Temperature Range
0 to +60° C
Temperature Coefficient
10.025%/° C
Cable
15 Feet
Mechanical
Dimensions
The following dimensions are for reference only:
FIG. 2-1 A DIMENSION
NOTE:
Cable dimension is for the Universal and Analog
scales only. DeviceNet cable length is different, see
DeviceNet Specification above.
FIG. 2-2 B DIMENSION
Six conductor shielded
15 Feet
A
B