Wiring the muting inputs, Time chart – KEYENCE SL-V Series User Manual
Page 100

3-8
System Configuration for the Muting Function
3-24
In
3
SL-V-M-NO3-E
Wiring the muting inputs
Output of the switch or sensor used as the muting device must be the same as the cable used.
Example: PNP output if PNP cable is used, or NPN output if NPN cable is used.
Also, the muting device must be able to handle a 3 mA current load.
Time chart
Brown
Blue
+24 V
Short-circuit current: 2.5 mA
0V
Light blue
Light blue/black
(Muting input 2)
(Muting input 1)
Transmitter
Sensor A1
Sensor A2
0V
+24 V
Light blue
Brown
Blue
Light blue/
black
Transmitter
(Muting input 2)
(Muting input 1)
Sensor A1
Sensor A2
Short-circuit current: 2.5 mA
When using the PNP output cable
When using the NPN output cable
NOTE
Sensor A2
ON
OFF
Muted condition
Not muted condition
ON
OFF
Sensor A1
SL-V
No
interruption
Interruption
OSSD
ON
OFF
Light ON
Light OFF
Muting
lamp
Within approx. 5 min.
20 ms max.
Within 0.04 to 3 s
20 ms max.