KEYENCE SL-V Series User Manual
Page 85
Advertising

3-3
Light Interference Prevention Method
3-9
In
3
SL-V-M-NO3-E
(5) Installation with some distance to prevent light interference
When installing the SL-V in method 2, 3 or 4, installing the devices too closely may cause reflection in the
plane of detection and thus cause interference. Total prevention of light interference may not be possible
even following methods 1 to 5. The operator in charge must consider adequate light interference preven-
tion method according to the machine or system where the SL-V is installed.
X
Y
Receiv
er
T
ransmitter
T
ransmitter
Receiv
er
Operating
distance “X”
Minimum installation distance “Y”
Less than 3 m 0.26 m
3 m or more
X
tan5
= 0.0875 X
Transmitter
Receiver
Transmitter
Receiver
5
o
5
o
X
Y
NOTE
Advertising