Example of a muting lamp error, State information output – KEYENCE SL-V Series User Manual
Page 46

2-8
State Information Output
2-22
2
SL-V-M-NO2-E
Example of a muting lamp error
• When using a PNP output type cable to connect to a PNP input device
• When using an NPN output type cable to connect to an NPN input device
• When using a PNP output type cable to connect to an NPN input device
• When using an NPN output type cable to connect to a PNP input device
AUX
2 pulses (muting function active)
4 pulses (muting lamp error)
Muted condition
40 ms min.
120 ms
20 ms*
20 ms*
20 ms*
20 ms*
ON
OFF
State information
output 1
ON
OFF
State information
output 2
ON
OFF
ON
OFF
OSSD
* This is 100 ms when the
"Pulse speed" on the
SL-VH1S is set to "Slow".
AUX
2 pulses (muting function active)
4 pulses (muting lamp error)
Muted condition
40 ms min.
120 ms
20 ms*
20 ms*
20 ms*
20 ms*
ON
OFF
State information
output 1
ON
OFF
State information
output 2
ON
OFF
ON
OFF
OSSD
* This is 100 ms when the
"Pulse speed" on the
SL-VH1S is set to "Slow".