APPENDIX B: KISTLER-MORSE

®

PROTOCOL SERIAL COMMANDS

Request from Master

Response from STXplus

>aaL4000000dssr

Ar

Format

>01L4112r

Ar

Example

‘K5’ Command — Read AB-RIO Rack Size
This command is sent by the master to request the STXplus to send the AB-RIO rack size. The
range of acceptable values is 0-3 where 0 for 1/4, 1 for 1/2, 2 for 3/4, or 3 for full. For this
example, the master requests AB-RIO rack size for an STXplus at address 01 which returns 0
(1/4) and a checksum of 50.

Request from Master

Response from STXplus

>aaK5ssr

A000000dssr

Format

>01K5E1r

A000000050r

Example

‘L5’ Command — Write AB-RIO Rack Size
This command is sent by the master to set the AB-RIO rack size of an STXplus. The range of
acceptable values is 0-3 where 0 for 1/4, 1 for 1/2, 2 for 3/4, or 3 for full. For this example, the
master sets AB-RIO rack size for an STXplus at address 01 to 1 (1/2). Any of the 6 leading zeros
may be omitted.

Request from Master

Response from STXplus

>aaL5000000dssr

Ar

Format

>01L5113r

Ar

Example

‘K6’ Command — Read AB-RIO Last Rack
This command is sent by the master to request the STXplus to send the AB-RIO last rack. The
range of acceptable values is 0-1 where 0 is Yes or 1 is No. For this example, the master requests
AB-RIO last rack for an STXplus at address 01 which returns 0 (No) and a checksum of 50.

Request from Master

Response from STXplus

>aaK6ssr

A000000dssr

Format

>01K6E2r

A000000050r

Example

‘L6’ Command — Write AB-RIO last rack
This command is sent by the master to set the AB-RIO last rack of an STXplus. The range of
acceptable values is 0-1 where 0 is Yes or 1 is No. For this example, the master sets AB-RIO last
rack for an STXplus at address 01 to 1 (Yes). Any of the 6 leading zeros may be omitted.

Request from Master

Response from STXplus

>aaL6000000dssr

Ar

Format

>01L6114r

Ar

Example

‘K7’ Command — Read AB-RIO Mode
This command is sent by the master to request the STXplus to send the AB-RIO mode. The
range of acceptable values is 0-1 where 0 is Discrete or 1 is Block. For this example, the master
requests AB-RIO mode for an STXplus at address 01 which returns 0 (Discrete) and a checksum
of 50.

B-30

Advertising