Before You Begin

When you determine where to install the switch, verify that these guidelines are met:

•

Airflow around the switch and through the
vents is unrestricted.

Note

We strongly recommend that you allow
at least 3 inches (7.6 cm) of clearance
around the ventilation openings.

•

Temperature around the switch does not
exceed 113°F (45°C).

•

Humidity around the switch does not exceed
85 percent.

•

Altitude at the installation site is not greater
than 10,000 feet (3,049 meters).

•

Do not place any items on the top of the
switch.

•

The bottom of the switch might be hot to the
touch if the switch is operating at its
maximum temperature 113°F (45°C) and is in
an environment that exceeds normal room
temperature (such as in a closet, in a cabinet,
or in a closed or multirack assembly).

•

Allow at least 1.75 inches (4 cm) of clearance
above each switch in the rack.

•

When placing the switch on a flat horizontal
surface without the magnet, we strongly
recommend that you attach the rubber feet to
the switch. Doing so helps prevent airflow
restriction and overheating.

•

Do not stack switches or place switches
side-by-side, unless they are separated all
around by at least 3 inches (7.6 cm) of
clearance from each other.

•

Do not wall-mount the switch with its front
panel facing up or to the side. We
recommend wall-mounting the switch with
its front panel facing down to prevent
airflow restriction and to provide easier
access to the cables.

•

Clearance to the switch front and rear panels
meets these conditions:

–

Front-panel LEDs can be easily read.

–

Access to ports is sufficient for
unrestricted cabling.

–

AC power cord can reach from the AC
power outlet to the connector on the
switch rear panel.

•

Cabling is away from sources of electrical
noise, such as radios, power lines, and
fluorescent lighting fixtures.

•

For 10/100 and 10/100/1000 ports, the cable
length from a switch to an attached device
cannot exceed 328 feet (100 meters).

•

For cable lengths for small form-factor
pluggable (SFP) modules, see the
documentation that shipped with the
module.