INITIAL START-UP

4-11

AERCO recommends that you do not
change this code.

7. Press the SET button again to enter the

code. The first parameter label (SP) will
appear in the display.

8.

Using the ▲ and ▼ arrow keys, select
parameter P1.

9. Press SET to view the value stored in

memory.

10. If the desired value is not displayed, modify

the setting using the ▲ and ▼ arrow keys.
The value can be changed from -10° to +10°

offset. Press SET to enter the value and exit
to the text parameter.

11. To exit the programming mode, press the

SET

and ▼ buttons simultaneously, or

simply wait one minute and the display will
automatically exit the programming mode.

12. Once the programming mode has been

exited, the display will show the current
outlet water temperature of the boiler.





Advertising