SAFETY PRECAUTIONS

1-1

SECTION 1 -- SAFETY PRECAUTIONS

1.1 WARNINGS & CAUTIONS

Installers and operating personnel MUST, at all

times, observe all safety regulations. The

following warnings and cautions are general and

must be given the same attention as specific

precautions included in these instructions. In

addition to all the requirements included in this

AERCO Instruction Manual, the installation of

units MUST conform with local building codes,

or, in the absence of local codes, ANSI Z223.1

(National Fuel Gas Code Publication No. NFPA-

54) for gas-fired heaters and ANSI/NFPASB for

LP gas-fired heaters. Where applicable, the

equipment shall be installed in accordance with

the current Installation Code for Gas Burning

Appliances and Equipment, CGA B149, and

applicable Provincial regulations for the class;

which should be carefully followed in all cases.

Authorities having jurisdiction should be

consulted before installations are made.
See pages 1-2 through 1-4 for important

information regarding installation of units

within the Commonwealth of Massachusetts.

IMPORTANT

This Instruction Manual is an integral part of

the product and must be maintained in

legible condition. It must be given to the user

by the installer and kept in a safe place for

future reference.

IMPORTANT

Read the following restrictions prior to

installing the water heater:
1. The water heater can only be used for

applications where the chlorine concentra-

tions Do Not Exceed 4 mg/L which is the

Environmental Protection Agency limit for

chlorine concentrations in drinking water.
2. Do Not use this heater for a pool heating

application.
3. If this heater was ordered with the optional

copper-lined, carbon steel shell, items 1 and

2 Do Not Apply. (Contact your local AERCO

representative to verify heater shell material.

WARNINGS!

MUST BE OBSERVED TO PREVENT

SERIOUS INJURY

.

WARNING!

BEFORE ATTEMPTING TO PER-

FORM ANY MAINTENANCE ON THE

UNIT, SHUT OFF ALL GAS AND

ELECTRICAL INPUTS TO THE UNIT.

WARNING

DO NOT USE MATCHES, CANDLES,

FLAMES, OR OTHER SOURCES OF

IGNITION TO CHECK FOR GAS

LEAKS.

WARNING!

THE EXHAUST VENT PIPE OF THE

UNIT OPERATES UNDER A POSI-

TIVE PRESSURE AND THERE-

FORE MUST BE COMPLETELY

SEALED TO PREVENT LEAKAGE

OF COMBUSTION PRODUCTS INTO

LIVING SPACES.

WARNING!

FLUIDS UNDER PRESSURE MAY

CAUSE INJURY TO PERSONNEL

OR DAMAGE TO EQUIPMENT

WHEN RELEASED. BE SURE TO

SHUT OFF ALL INCOMING AND

OUTGOING WATER SHUTOFF

VALVES. CAREFULLY DECREASE

ALL TRAPPED PRESSURES TO

ZERO BEFORE PERFORMING

MAINTENANCE.

WARNING!

ELECTRICAL VOLTAGES OF 120

VAC ARE USED IN THIS EQUIP-

MENT. THEREFORE THE COVER

ON THE UNIT’S POWER BOX

(LOCATED ON THE FRONT RIGHT

SIDE OF THE UNIT UNDER THE

HOOD AND SHEET METAL SIDE

PANEL) MUST BE INSTALLED AT

ALL TIMES, EXCEPT DURING

MAINTENANCE AND SERVICING.

CAUTIONS!

Must be observed to prevent equipment

damage or loss of operating effectiveness

.