SK-ACP

Installation & Operating Manual

B-2

PHYSICAL

Depth

3.0”

(7.62 cm)

Width

10.0”

(25.40 cm)

Height

11.0”

(27.94 cm)

Weight

68.8 oz

(1.95 kg)

Housing Material is All Steel; Color is Beige

POWER REQUIREMENTS

16.5-24 VAC, 20 VA or 16-30 VDC, 100 mA plus reader current draw

Power Supply Sold Separately

*

A 12 VDC Power Supply may be used if connected to Battery Back-Up Leads.

BACK-UP BATTERY

12 V, 1.2 - 6 Ah (Optional, Sold Separately)

CARD READERS

Connect two card readers with two-line Wiegand output, up to 40 bits.
Provides 14 VDC, 150 mA max. power for each card reader.

SOFTWARE

SK-NET

TM

Software Version 2.0 or greater

OUTPUTS -

2 Per Door (Total of 4)

Latch & Alarm Shunt

DPDT contact, 2A, up to 220 VAC or 30 VDC

Auxiliary

DPDT contact, 2A, up to 220 VAC or 30 VDC

INPUTS -

2 Per Door (Total of 4)

Auxiliary 1

Requires SPST contact closure

Auxiliary 2

Requires SPST contact closure

COMMUNICATION

RS-232

5-Wire Shielded Cable, up to 38.4K baud, full duplex, (8N1)

RS-485

Single Twisted Pair, shielded cable with a signal ground

Wiegand Input (2)

Programmable up to 40 bits
14 VDC @ 150 mA supplied to each reader,

Modem

Requires Hayes compatible - 1.2 to 38.4k baud

Printer

Serial Printer (or Parallel printer with serial converter)

ENVIRONMENT

Ambient Temperature

-40° F to 158° F (-40° C to 70° C)

Humidity

0% to 95% relative humidity (non-condensing)

OPERATIONAL

Card Capacity

65,535/Door (Highest card number = 65,535)

Time Zones

15 for card access, one door unlock; full week plus
holiday in one-half hour segments; 32 programmable
holidays; selectable automatic daylight saving time.

Facility Code

Up to 16 different codes simultaneously (max. # of cards 65,535)

Latch/Alarm Shunt Timer

Programmable from 1/4 to 30 seconds

Antipassback

Real or Timed (1 to 30 minutes); hard or soft

Auxiliary Inputs (2)

Programmable for door monitor, tamper monitor, remote
open, remote inactive, bell, arming circuit or user defined

Auxiliary Output (1)

Output is programmable to activate under one of many
possible alarm conditions, time zone or card violations.

Limited Use Cards

4,000 (in a block within 65,535) programmable from
1-500 uses, days, weeks or number of days after first use.

Transaction Storage

4,864 events

Memory

Non-volatile

This product complies with UL 294 Standards, CE (European Standards), and with Part 15 of Class B FCC Rules.

Per Door

{

SPECIFICATIONS