SK-ACP

Installation & Operating Manual

2.2

Setup Location Properties

1. Select SK-NET™’s Explorer (Globe Icon).

2. Right click on the location name, and select Properties from the pull down menu.

Click on the “Connection” tab.
a) Uncheck “Gateway (RS232)”. Baud rate should automatically change to 38,400.
b) In the box labeled “Connect Using” select the PC serial COM port to which the converter is

connected.

c) Be sure the “Local Connect” box is checked.
d) Click on “Connect”.

2.3

Voltage Measurements

1. Voltages: Measure voltages at the converter.

a) Measure input voltage from the converter power supply. Should read from 9vDC to 16vDC.
b) Measure the voltage from the GND or (- side of the power supply) to TD (A), should read 0 v DC,

from GND to TD (B), should read from 2.5 to 5v DC.

2.4

Power Reset (for initial setup only!)

1. Power Reset: This will change the node address, set password to 12345 (default), and set the baud

rate to 38,400 (default).
a) Turn off the power to the reader, push the reset button, turn on the power with reset button pushed

for approximately 3 seconds after turning on power. Repeat for all readers.

2.5

Steps to find new readers

1. Right click on location name.

2. Select Connect. Message on Screen: “Connecting to location (Name), continue.” Click OK.

3. Message on Screen: “There are no readers in Location (Name), to be logged in. Scan for new readers

now?” Click YES. Message on screen: “Are there more than 20 readers in this location? Select “YES”
or “NO”.

4. Message on Screen: “New Readers Found!”, select OK. Now the software will make backup files for

all the settings in all of the readers except for the card status.