To test the Compact Flash. There are the following possible situations:

1

. If there is a Compact Flash inserted in the slot and there is not a malfunction, the name of the

Compact Flash zone and the message “OK” are shown.

2

. If there is a Compact Flash inserted in the slot, but it is a damaged Compact Flash, the name of

the Compact Flash zone and the message “Faulty” are shown.

3

. If there is not any Compact Flash inserted in the slot, the message “not present” is shown.

4

. If there is an User Compact Flash inserted in the slot, the message “USER CARTRIDGE” is

shown.

• C-CARD Connector

Indicates if there is a malfunction in the connector. It is used only in production.

15.5.3 Serial Ports

If you are having problems receiving data from the position-finding instrument, this test should help

determine the problem.

• Change Parameters

To change the parameters of the serial interface. This menu allows to select the Port (Signal Source)

between UART0 or UART1, the Baud Rate between 4800 or 9600, the Data Bits (Word Length)

between 7 or 8, the Parity between EVEN, ODD or NONE, the Stop Bits between 1 or , the

Polarity between “+” or “-”. Default settings are: Port = UART1, Baud Rate = 4800, Data Bits =

8, Parity = NONE, Stop Bits = 1, Polarity = +.

• Input Data Display

To allow the chart plotter to act as a computer terminal and display the incoming data exactly as

it received.

If the data displayed on the screen is unrecognizable, you may have selected the wrong input

parameters for your particular receiver, for example, NMEA-018 instead of NMEA-0183. Check

your receiver manual to be sure that you have selected the proper interface format. If the screen

is blank, you may have a broken connection, and no data is being received. Use ‘ZOOM IN’ to

stop (or continue after pause) data displaying, ‘ENT’ to show data in hex or ASCII mode (normal or

small) and ‘ESC’ to exit.