BG1100M Direct Spark Ignition Control Installation Instructions 15

Technical Specification

Product

BG1100M Direct Spark Ignition Control

Ignition Type

Direct

Ignition Source

High voltage spark, capacitive discharge

High Voltage Cable
Maximum Length

48 in. (1,220 mm) (Resistive wire only, rated for at least 15kV.)

Flame Sense Cable
Maximum Length

48 in. (1,220 mm)

Flame Detection Means

Flame Rectification

Flame Detection Type

Local or Remote

Minimum Flame Current

0.15 microamperes

Flame Failure Response
Time

2 second maximum

Maximum Spark Gap

0.2 in. (5.1 mm)

Number of Trials Before
100% Shutoff

One or Three

Trial-for-Ignition Time

4, 8, 10 or 20 seconds

Prepurge Time

0 (none), 15 or 30 seconds

Inter-Purge Time

0 (none) or 30 seconds

Retry (Recycle) Delay
Period

0 minutes (none)
5 minutes

Power Requirements

Control:
Operation Current:

24 VAC (+/- 20%), 50/60 Hz
0.2 A nominal + valves

Contact Rating

Valve:

2 A maximum

Wiring Connections

1/4 in. (6.35 mm) male spade

Maximum Firing Rate

400,000 Btu/hr (117 kW)

Ambient Operating and
Storage Temperature

-40 to 170

°F (-40 to 77°C)

Humidity

95% RH noncondensing

Type of Gas

Natural, Liquefied Petroleum (LP), Manufactured, Mixed or LP Gas-Air Mixture

Packaging

Bulk pack supplied to original equipment manufacturer (individual pack optional)

Bulk Pack Quantity

25

Pack Weight

14 lb (6.36 kg)

Agency Listing

CSA Certificate Number 246569-2161442

Specifications Standards

ANSI Standard Z21.20
CAN/CSA-C22.2 No. 199

The performance specifications are nominal and conform to acceptable industry standards. All agency
certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of
BASO products beyond these conditions is not recommended and may void the warranty. If the product is
exposed to water (dripping, spraying, rain, etc.) or other harsh environments, it must be protected. The original
equipment manufacturer or end user is responsible for the correct application of BASO products. For questionable
applications, please consult BASO Gas Products LLC. BASO Gas Products LLC shall not be liable for damages
or product malfunctions resulting from misapplication or misuse of its products.

1007 South 12th Street
PO Box 170
Watertown, WI 53094

Published in U.S.A.

1-877-227-6427

www.baso.com