BG1100M Direct Spark Ignition Control Installation Instructions 9
Continued
from previous page
Pilot is lit
No
Yes
Yes
No
After burner is
lit, do valves turn off
and start new
cycle?
Flame in
contact with spark or
sense electrode?
Adjust flame size or
electrode position.
Replace
module.
No
Two rod
flame sense?
Yes
Check wiring electrode
to SENSE terminal.
If OK replace module.
Control is
operating
normally.
Figure 5: Troubleshooting Flow Chart (2 of 2)