BG1100M Direct Spark Ignition Control Installation Instructions 7

No

Yes

Idle State

Call for heat

from the thermostat

POWER TO CONTROL

One second for

diagnostic routines

If pre-purge wait

flashing red LED once a

0.5 second until over

Turn on spark and

gas valve

start trial timer

Spark on 4 seconds

blinking red LED rapidly

spark off 1 second

Flame

on?

Flame

on?

Wait 0.5 second

Trial

over?

No

Turn on red LED

Yes

No

Turn gas

valve off

Yes

Retry

option?

Wait 5 minutes, blink

red LED every 4 seconds

TRIAL

TIME

LOOP

TRIAL

TIME

OVER

RESTART

Note: If the thermostat opens,
the control will turn off valve
and returns to the idle state.

Wait 0.1 second

checking memory and

relay driver circuits

OK

Flame

on?

Yes

No

Flame off

0.7 second?

Turn gas valve off
wait 0.7 second or

inter-purge blinking

red LED once a 0.5 second

Yes

No

FLAME LOST, TURN

OFF VALVES AND
TRY TO RE-LIGHT

FLAME ON

LOOP

RE-LIGHT

Note:

Error Codes

Lock out on timeout or fault detected,

turn off valve relays and spark loop blinking
error code until power off.

No flame in trial time.
Flame sense stuck on.
Valve relay driver fault.
Processor errors.

1 Blink
2 Blinks
3 Blinks
5 to 9 Blinks

Yes

Lockout

No

Figure 3: Sequence of Operation