Maintenance and Service

All Boekel laboratory products are designed to comply with IEC1010-1. No routine
maintenance is required. There are no user serviceable parts in this product.

8.1

Cleaning

Disengage power cord prior to cleaning. The glass dish has molded handles to allow
removal for easy cleaning. Paraffin build-up should be avoided around the top area of the
Tissue Bath. Paraffin and liquids should also be cleaned as quickly as possible from the
black chamber area to prevent glass dish heating problems. The outer casing may be
cleaned with water and a damp cloth. Do not submerge or immerse the Tissue Bath in
water. Before using any cleaning or decontamination method except those recommended
by the manufacturer, users should check that the proposed method would not damage the
equipment.

8.2

Replacement of Fuses

There are two supply fuses located in the fuse drawer. To replace the fuses:

• Disconnect the unit from the power supply.

• Remove the plug from the socket in the back of the unit.
• Pull back on the fuse drawer

• Pull out the fuse drawer

• Check and replace with the correct fuses if necessary. The fuses must be ¼” x

1 ¼” fast acting, rated 4A and 250V.

• Push the fuse drawer back in. Reconnect unit to the power supply.

9

.

Warranty

When used in laboratory conditions and according to these operating instructions, Boekel
Scientific warrants this product to be free of defective material and workmanship for a
period of two years from the date of manufacture. The liability of Boekel Scientific for
any defective equipment during the warranty period shall be limited to the repair of such
equipment or replacement thereof without charge for parts or labor.

10.

Service

It is required to obtain a Returned Material Authorization (RMA) number before any
Boekel products are returned for any reason. A Decontamination Certificate must be
completed, signed by the user, and returned to Boekel Scientific prior to receiving the
RMA number. Please be sure to mark the outside of the returned goods package with this
RMA number to ensure prompt handling.