Replace the Power Supply

Figure 27

Replacing the Power Supply

Caution

Do not mix power supplies in Cisco 7200 VXR routers. In dual power supply configurations, both power supplies
must be of the same type (two AC-input power supplies or two DC-input power supplies).

Caution

To ensure adequate airflow across the router power supplies, a power supply or a power supply filler plate must be
installed in each power supply bay. Figure 18 shows a Cisco 7206VXR with an installed power supply filler plate.

Caution

The DC return connection to this system is to remain isolated from the system frame and chassis (DC-I).

Step 1

Power down the router.

Step 2

Disconnect the router from the power source (3).

Step 3

Unscrew the captive installation screws (4).

Step 4

Grasp the handle (5) and pull the power supply out of the chassis.

Step 5

Insert a new power supply of the same type that you removed and tighten the captive installation screws.

Step 6

Connect the power supply to the power source and power up the router.

Note

When powering off the router, wait 30 seconds before powering it on again.

1

Power switch

4

Captive installation screws

2

PWR OK LED

5

Handle

3

AC/DC power input connection