LIFT OUT TAB TO UNCLIP

TERMINAL COVER FROM

THERMOSTAT

Tighten

terminals 2 and 3 to ensure proper

electricai

connection.

5,

FIGURE 16.

Remove the

screws from terminal 2 of

the element,

and

move

the looped

end

of the wire

aside.

FIGURE 17.

The buss bar is

labeled

5500 W. Place the buss bar over

terminals 2

and

3 with the 5500 W visible. Install the extra

screw provided into terminal 3.

AWARNING

Fire and Explosion Hazard

Failure to tighten screws can

cause afire.

Failure to do this could result in

death, serious bodily injury, or

property damage.

Failure to tighten

terminal screws

can cause a fire which

can

result in DEATH,

SERIOUS BODILY

INJURY, OR PROPERTY

DAMAGE,

9. Replace terminal

cover on

thermostat making

sure that

the locking tabs on

the

terminal cover are in place.

AWARNING

Fire and Explosion Hazard

Thermostat

must

be

flush

against the tank.
Make sure terminal cover is in

place

and

the

insulation

replaced.
Failure to do this could result in

death, serious bodily injury, or

property damage.

7. The

wire

removed from terminal 2 has a looped end.

It

must remain looped and

now

be placed (as

shown)

on

top

of

the buss bar,

over

the

opening

of

terminal 2,

and

secured using

the remaining screw.

Make

sure the

thermostat

is flush against the tank, the

terminal

cover is in place, and the

insulation

is replaced. Failure to do

so

can result

in DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE,

10. Replace the insulation

cap

with

handle back in place so

that it completely covers

the

thermostat and element.

FIGURE 19.

13