The length in any ground return path does not exceed

6 feet.

The

circuit

conductors contained therein

are

protected

by overcurrent devices rated

at

20 amperes or less.

The conduit or tubing is terminated in fittings approved

for

grounding.

NOTE: If you have purchased a three wire connection wafer

heater but you are not on a “Time Clock” or “Off Peak” meter

and

have a

standard two wire

connection power

supply,

simply follow the connection diagram in

block

3 of the three

wire connection diagram.

6.

Use wire nuts and connect

the

power supply wiring to the

wires inside

the

water

heater’s

junction box.

For

complete

grounding

details and

all allowable

exceptions,

refer to the current edition of the NEC - National Eiectrical Code

NFPA70.

4. A standard 1/2"

conduit

opening has been made in the water

heater junction box for the conduit

connection.

5. Wiring Diagrams, see

“ W ir in g D ia g r a m s ”

section have

been

supplied

showing

the

two

most

common

types

of

connections between the water heater and the power supply.

You can easily

see

which type

connection

you have by

removing the junction box cover on top of the water heater.

Two Wire Connection Diagrams: is the most common

requiring you to simply connect red

to

red,

black

to

black, and

the ground wire

to

the green

ground

screw

in the junction box of

the wafer heater.

Three Wire Connection Diagram: is used when you

are

connecting

the water

heater

to a power supply

that has a “Time Clock” or “Off Peak” meter. To make

these

connections

refer

to block 1 or 2 in this wiring

diagram for

the

type of

system

you

have.

7. The water heater must be electrically “grounded” by the

installer, A

green

ground

screw

has

been

provided on the

water heater’s junction

box.

Connect ground wire to

this

location.

8.

Replace

the wiring junction

cover

using the

screw

provided.

FIGURE 23.