8,

Clean the area around the element opening. Remove any

sediment from or around the element opening, inside the
tank,

9, If you are cleaning the element you have removed, do so by

scraping or soaking in vinegar or a de-iiming solution.

A

WARNING

Fire Hazard and

Electric Shock Hazard

Do not use replacement elements with

any voltage other than shown on the

model rating plate.

Failure to use the correct voltage shown

on the model rating plate could result in
death, serious bodily injury, or property
damage.

Replacement elements must (1) be the same voltage and (2)
no greater wattage than listed on the model rating plate affixed

to the water heater.

10. A new gasket should be used in all cases to prevent a

possible water leak. (See Element Gasket in the “Parts
Order List ” Chart). Place the new element gasket on the
thread side of the cleaned or new element and screw into
tank, securing tightly using an element wrench.

FIGURE 37.

11. Close the wafer heater drain valve by turning the handle to

the right (clockwise). The drain valve id on the lower front of
the water heater.

12. Open the cold water supply valve to the water heater.

Never use this water heater unless it is completely full of water.
To prevent damage to the tank and heating element, the tank
must be filled with wafer. Water must flow from the hot wafer

faucet before turning “ON” power.

14, Check element for water leaks, if leakage occurs, tighten

element or repeat steps 2 and 3, remove element and
reposition gasket. Then repeat steps 10 through 14,

15. Reconnect the two wires to the element and then check to

make sure the thermostat remains firmly against the
surface of the tank.

FIGURE 38.

16. Replace terminal cover on thermostat making sure that

the locking tabs on the terminal cover are in place.

FIGURE 39.

17, Place the insulation cap with handle back in place so that

it completely covers the thermostat and element.

NOTE: The cold water supply valve must be left open when the

wafer heater is in use.

13. To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the
water heater and the piping.

CAUTIO

Improper installation and use may result

in property damage.

Fill tank with water before operation.

21