Stardance direct vent/natural vent gas heater, Wall centerline from floor, Wall and ceiling clearances – Vermont Casting SDDVT User Manual

Page 7: Hearth requirements

Advertising
background image

7

Stardance Direct Vent/Natural Vent Gas Heater

20012734

ST128b
Stardance
flue centerline
9/28/00 djt

C

L

C

L

B

D

C

A

Parallel Installation: Minimum Clearance

and Flue Centerline, Direct Vent and

Natural Vent

ST128b

Stove Clearances:

A: 4” (102 mm)

B: 4” (102 mm)

Pipe Centerlines:

C: 15¹⁄₂” (395 mm)

D: 9” (229 mm)

Fig. 3 Parallel installation, minimum back and side clear-
ances, and flue centerlines.

Corner Installation:

Minimum Clearance and Flue Centerline,

Direct Vent and Natural Vent

ST129b
Stardance
corner specs
9/28/00 djt

A

A

B

B

Stove Clearance: A: 4” (102 mm)
Pipe Centerline:

B: 14¹⁄₂” (370 mm)

ST129b

Fig. 4 Corner installation, minimum corner clearance and flue
centerline.

Wall Centerline from Floor

ST131b

Stardance

wall thimble

9/28/00 djt

A

Direct Vent Only

ST131b

Effective Minimum
Wall Thimble

56” (1480 mm) (CFM Pipe)

Centerline

52” (1378 mm) (Simpson Duravent Pipe)

Fig. 5 Minimum wall thimble centerline.

Wall and Ceiling Clearances

A

C

D

ST101b

Stardance

Direct Vent

Min. Clrnc

9/28/00 djt

B

ST101b

A: Rear Wall

4” (102 mm)

B: Min. Clearance

45¹⁄₄” (1154 mm)*

C: Min. Alcove Height

72” (1830 mm)

D: Max. Alcove Depth

48” (1220 mm)

Sidewall Clearance

4” (102 mm)

Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Stardance Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.