El-04189

4) Preset tare subtraction (A)

Initial mode:

Ex.) 1.50 Tare weight

1

WEIGHT

PRICE/lb

TOTAL PR

0.00

P

0000

0.00

P

0150

Depress:

NET

\ 1/

-1.50

0000

5) Preset tare subtraction (B) : Random Items PLU

WEIGHT

PRICE/lb

TOTAL PRICE

Initial mode:

0.00

0000

PLU

0.00

0.00

0.00

I

Ex.) Tare weight 1.501 lb

Index:

1

Depress:

NET

\ 1/

0.00

1.50

0.00

-1.50

0.00

* As for 151b capacity scale, entry weight for preset tare must be integer times of 5.

Ex.) 1.05,0.05,0.10, 1.151b

The above does not hold true with the 301b scale.

* Unit Price called up from PLU file cannot be used for preset tare input.

* Tentative unit price change after calling up from PLU file cannot be excuted except Random Items PLU

and open unit price.

NOTE 1; The main circuit in the unit is turned ON when the power plug is connected to the AC outlet. The

power of the load cell cannot be turned OFF by the control lock key.

NOTE 2: When the control lock key is turned to "REG" position within about 16 seconds after the power

plug is connected to the AC outlet, the test scanning sequence is made, then initial mode is dis­

played and the scale is ready for use.

NOTE 3; © After test scanning sequence, if initial weight is in un-stable condition, all "8" indicated on dis­

plays will go on and off.

® After test scanning sequence, if initial weight is out of the zero range which is very important

limits for starting operation, "------- " will be indicated on weight display.

If this situation occurs, check whether the platter is touching to something or not, weight being

on the platter or not and setting place of scale being on stable or not.

NOTE 4: Depressing direct key which is not stored in PLU data beforehand causes the machine to enter to

error mode.

NOTE 5: In case that tare weight is over 20 div. (301b scale: 0.201b, 1 51b scale: 0.1 Olb), please be sure not

to issue the tare label by setting Mode switch to MANUAL position.