Configuring a redundant circuit, Configuring a redundant circuit -2 – Cabletron Systems SEHI-22/24 User Manual

Page 46

Advertising
background image

Repeater Redundancy

4-2

Setting Network Circuit Redundancy

spmarun r4red <IP address> <community name>

The main Repeater Redundancy window,

Figure 4-1

, will appear.

Figure 4-1. The Repeater Redundancy Window

Configuring a Redundant Circuit

To establish or edit a redundant circuit:

1.

In the Repeater Redundancy window, click mouse button 1 on the repeater
interface for which you would like to edit or establish a redundant circuit, then
click

. The Channel X Redundancy window,

Figure 4-2

, will

appear.

NOTES

The spmarun script invoked first in the above command temporarily sets the environment
variables SPMA needs to operate; be sure to use this command any time you launch an
application from the command line. The script is automatically invoked when you launch
the application from the icon menu or from within the Hub View.

If you wish to change any redundancy settings, be sure to use a community name with at
least Read/Write access. If you only wish to view
current settings, a community name
with Read access will be sufficient.

If there is a hostname mapped to your SEHI’s IP address, you can use <hostname> in
place of <IP address> to launch this application. Please note, however, that the hostname
is not
the same as the device name which can be assigned via Local Management and/or
SPMA; you cannot use the device name in place of the IP address.

Advertising