Tube Station 2 OPERATORS’ MANUAL

6

OUTPUT SECTION

Output Gain

The output level may be adjusted between !30dB’s and +5dB’s

to compensate for level changes caused by compression and

limiting.

Limit

This is a Hard level limiter fixed at +16dB (ref +4dBu). A led

indicates when limiting occurs.

Meters

A eight-section LED meter display the signal level (from !35dB

to 0dB) that is sent to the Digital Output (if fitted).

Analogue Output

Sets the overall Analogue output level of the channel from Off to

+16dB. Adjusting this control does not change the meter levels.

Bypass

Switches the unit into Bypass to allow comparison with the input

signal, illuminates the status LED.

LINKING

Stereo Link

Depressing this switch configures the unit in stereo mode where

the left hand channel controls act as masters for both audio

channels. The same degree of gain reduction is applied to both

audio channels to prevent image shifting which would otherwise

occur whenever the left and right signal dynamics varied from

each other by any significant degree.

Note that whilst the knobs are linked and controlled by the left

channel (ch1) the switches, Tube Active and Bypass, remain

independent for each channel.