EVCO EVR274N9 User Manual

Page 9

Advertising
background image

EVCO S.p.A. | Code 104R200E114 | Page 9 of 10 | PT 14/13 | version 1.1

i9

1

999

min

240

240

240

240

240

240

240

time that must pass in absence of multifunction output alarms (code “iA”) so that
the alarm counter is reset (only if i0 and/or i5 = 9)

i10

0

999

min

0

0

0

0

0

0

0

time without activations of the door switch input (on condition that the cabinet
temperature has reached the working set-point) in order that function “energy
saving” is activated (it has effect on the evaporator fan only if F0 = 1, 2, 3 or 4)
0

=

the function will never be activated due to the effect of this condition

i13

0

240

- - -

180

180

180

180

180

180

180

number of door switch input activations such as to provoke the defrost activation
0

=

defrosting will never be activated due to the effect of this condition

i14

0

240

min

32

32

32

32

32

32

32

minimum duration of the door switch input activation such as to provoke the defrost
activation
0

=

defrosting for this condition will never be activated

PARAM.

MIN.

MAX.

U.M.

EVR221 EVR261 EVR202 EVR203 EVR263 EVR204 EVR264 DIGITAL OUTPUTS
EVR231 EVR271 EVR232 EVR233 EVR273 EVR234 EVR274

u0

0

7

- - -

not avail.not avail.

7

not avail.not avail.not avail.not avail. operation controlled by second output (32)

0

=

CELL LIGHT - in this case the key and parameters i0, i5 AND u2 will be
activated

1

=

DEMISTER RESISTORS - in this case the key and parameter u6 will be
activated

2

=

AUXILIARY OUTPUT - in this case the key and parameters i5 and u2 will
be activated

3

=

ALARM OUTPUTS - in this case parameter u4 will be activated

4

=

DOOR RESISTORS - in this case parameter u5 will be activated

5

=

RESISTORS FOR NEUTRAL AREA OPERATION - in this case parameter u7
will be activated

6

=

EVAPORATOR FAN - in this case parameters d7, d16, F, i0 and i10 will be
activated

7

=

DEFROST - in this case parameters d1, d7 and d16 will be activated

u0

0

1

- - -

not avail.not avail.not avail.

1

1

not avail.not avail. utility managed by the second output (32)

0

=

CELL LIGHT - in this case the key and parameters i0 and u2 will be
activated

1

=

DEFROSTING - in this case, the d0... d22 parameters will be activated

u1

0

6

- - -

not avail.not avail.not avail.not avail.not avail.

0

0

operation controlled by fourth output (32)
0

=

CELL LIGHT - in this case the key and parameters i0, i5 AND u2 will be
activated

1

=

DEMISTER RESISTORS - in this case the key and parameter u6 will be
activated

2

=

AUXILIARY OUTPUT - in this case the key and parameters i5 and u2 will
be activated

3

=

ALARM OUTPUTS - in this case parameter u4 will be activated

4

=

DOOR RESISTORS - in this case parameter u5 will be activated

5

=

RESISTORS FOR NEUTRAL AREA OPERATION - in this case parameter u7
will be activated

6

=

CONDENSER FAN - in this case parameters P4, F11 and F12 will be
activated

u2

0

1

- - -

not avail.not avail.

0

0

0

0

0

enabling of manual switch on/switch off of the cell light or the auxiliary output when
the device is switched off(only if u0/u1 = 0 or 2) (33)
1

=

YES

u4

0

1

- - -

not avail.not avail.

1

not avail.not avail.

1

1

enabling of alarm output deactivation with the silencing of the buzzer (only if
u0/u1 = 3)
1

=

YES

u5

-99

99,0 °C/°F (1)not avail.not avail. -1,0

not avail.not avail.

-1,0

-1,0

temperature of the cell below which the door resistors are switched on
(“u5 - 2,0 °C/4 °F, only if u0/u1 = 4) (9)

u6

1

120

min

not avail.not avail.

5

not avail.not avail.

5

5

operating time of demister resistors (only if u0/u1 = 1)

u7

-99

99,0 °C/°F (1)not avail.not avail. -5,0

not avail.not avail.

-5,0

-5,0

neutral area value (relative to the work set-point, i.e. “work set-point + u7) (only
if u0/u1 = 5) (34)

u8

- - -

- - -

- - -

not avail.not avail. - - -

not avail.not avail. - - -

- - -

reserved

u9

0

1

- - -

1

1

1

1

1

1

1

enabling the buzzer
1

=

YES

PARAM.

MIN.

MAX.

U.M.

EVR221 EVR261 EVR202 EVR203 EVR263 EVR204 EVR264 ENERGY SAVING
EVR231 EVR271 EVR232 EVR233 EVR273 EVR234 EVR274

HE2

0

999

min

0

0

0

0

0

0

0

maximum duration of the “energy saving” function activated due to the effect of
absence of door microswitch input activation
0

=

the function will last until the input is activated

PARAM.

MIN.

MAX.

U.M.

EVR221 EVR261 EVR202 EVR203 EVR263 EVR204 EVR264 SERIAL NETWORK
EVR231 EVR271 EVR232 EVR233 EVR273 EVR234 EVR274

LA

1

247

- - -

247

247

247

247

247

247

247

device address

Lb

0

3

- - -

2

2

2

2

2

2

2

baud rate
0

=

2.400 baud

1

=

4.800 baud

2

=

9.600 baud

3

=

19.200 baud

LP

0

2

- - -

2

2

2

2

2

2

2

parity
0

=

none (no parity)

1

=

odd

2

=

even

Notes:
(1)

the unit of measurement depends on P2

(2)

Properly set the parameters corresponding to the regulators after modifying parameter P2

(3)

the value depends on parameter P2 (0.1 °C or 1 °F)

(4)

if parameter r8 is set at 1, the “energy saving” function and the defrosting functions will not be enabled

(5)

the parameter has effect even after an interruption in the power supply that occurs while the device is switched on (5) the parameter has effect even after an interruption in
the power supply that occurs while the device is switched on

(6)

the time established with the parameter is counted even when the device is switched off

(7)

if parameter C1 is set to 0, the delay after the end of the cell probe error will be 2 min

(8)

if parameter C2 is set to 0, the device will function as if parameter C18 were set to 0

(9)

The parameter differential is 2.0 °C/4 °F

(10)

if when the device is switched on, the condenser temperature is already above that established in parameter C7, then parameter C8 will not have effect

(11)

the device verifies the mains voltage at established intervals with parameter C2; if there is a power cut, the count of the number of switch-ons aborted will be reset.

(12)

the device memorises the defrosting interval count every 30 minutes; the modification of parameter d0 has effect from the conclusion of the previous defrosting interval (or the
activation of defrosting in manual mode)