Connecting to the Network

HSIM-FE6 User’s Guide

2-11

4.

Verify that a link exists by checking that the port receive LED is ON
(flashing amber, blinking green, or solid green). If the receive LED is
OFF and the transmit LED is not blinking amber, perform the
following steps until it is ON:

a.

Check that the power is turned on for the device at the other end of
the link.

b.

Verify proper crossover of fiber strands between the port on the
HSIM-FE6 and the fiber optic device at the other end of the fiber
optic link segment.

c.

Verify that the fiber connection meets the dB loss specifications
outlined in

Appendix B

.

If a link has not been established, refer to

Chapter 3

,

LANVIEW LEDs

,

before contacting the Cabletron Systems Global Call Center. Refer to

Section 1.5

for details.

2.4.2

Connecting a Twisted Pair Segment
to the FE-100TX

An FE-100TX has an internal crossover switch. When connecting a
workstation, use a straight-through cable and set the FEPIM crossover
switch shown in

Figure 2-5

to the crossed over position marked with X.

When connecting networking devices, such as another bridge, repeater, or
router, use a straight-through cable and set the FEPIM crossover switch
shown in

Figure 2-5

to the straight-through position, marked with =.

Figure 2-5

FE-100TX Crossover Switch

FE-100TX

10

100

=

x

fecrossover

Position =
(not crossed over)

1. TX+
2. TX-
3. RX+
4. NC

5. NC
6. RX-
7. NC
8. NC

Position X
(crossed over)

1. RX+
2. RX-
3. TX+
4. NC

5. NC
6. TX-
7. NC
8. NC