EVCO EVXS815P9 Installer manual User Manual
Page 32

EVCO S.p.A.
EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 32 of 60
r7
-50.0
99.0
°C/°F (1)
0.0
work set-point during blast chilling; also work set-point
during the soft deep freezing phase (cabinet temperature);
see also parameter r0
r8
-50.0
99.0
°C/°F (1)
-40.0
work set-point during deep freezing (cabinet temperature);
see also parameter r0
r9
-50.0
99.0
°C/°F (1)
-20.0
work set-point during hard blast chilling phase (cabinet
temperature); see also parameter r0
r10
-50.0
99.0
°C/°F (1)
2.0
work set-point during post blast chilling storage (cabinet
temperature); see also parameter r0
r11
-50.0
99.0
°C/°F (1)
-20.0
work set-point during post deep freezing storage (cabinet
temperature); see also parameter r0
r12
-50.0
99.0
°C/°F (1)
5.0
work set-point during pre-cooling (cabinet temperature);
see also parameter r0
r13
-50.0
99.0
°C/°F (1)
15.0
end temperature of the temperature-controlled hard blast
chilling phase (temperature detected by the needle probe)
r14
10
100
%
60
duration of the time-controlled hard blast chilling phase
(intended as a percentage of the value established with
parameter r1); also duration of the time-controlled soft
deep freezing phase (intended as a percentage of the value
established with parameter r2)
r15
-50.0
99.0
°C/°F (1)
65.0
temperature below which the count of the maximum
temperature-controlled
blast
chilling
and
maximum
temperature-controlled
deep
freezing
is
started
(temperature detected by the needle probe)
r16
0
2
- - - -
1
type of operating cycle that can be selected
0 = blast chilling and storage
1 = blast chilling and storage or deep freezing and
storage
2 = deep freezing and storage