EVSX815 | Installer manual ver. 1.3 | Code 144XS815E134
page 54 of 60
14
TECHNICAL DATA
14.1
Technical data
Purpose of the device:
blast chiller controller.
Execution:
user interface
control module
board without cover
board without cover.
Dimensions:
user interface
control module
156.0 x 45.0 x 24.0 mm (6.141
x 1.771 x 0.944 in ;L x H x P).
99.0 x 108.0 x 24.0 mm (3.897
x 4.251 x 0.944 mm; L x H x
D).
Installation:
user interface
control module
rear of panel, with M3 threaded
studs
on flat surface, with spacers.
Protection rating:
user interface
control module
IP00.
IP00.
Connections:
user interface
control module
extractable
screw
terminal
board (control module).
fixed
screw
terminal
board
(user interface and inputs), 6.3
m faston (0.248 in, power
supply and outputs), 6 pole
connector (serial port).
The maximum length of the user interface-control module
connection is 20 m (65.614 ft).
Temperature of use:
from 0 to 55 °C (from 32 to 131 °F).
Storage temperature:
from -25 to 60 °C (from -13 to 140 F).
Humidity for use:
from 10% to 90% relative humidity without condensate.
Pollution situation:
2.
Power supply:
user interface
control module