Radiance direct vent gas heater – Vermont Casting RADVTCB User Manual

Page 38

Advertising
background image

38

38

Radiance Direct Vent Gas Heater

20012697

2. Remove and replace plug on lower right hand side

of the valve; Red for LP and Blue for NG. (Page 32,
Fig. 57)

3. Remove motor top cap using a standard slotted

screwdriver. Depress and turn center plunger until
arrow points to correct screw. Red for LP and Blue
for NG. NOTE: Plunger will “snap” into NG position
when arrow is close to blue screw. It will not “snap”
at LP (Red) position. (Fig. 66)

CO105a

gas conversion

Pilot

1/28/00 djt

Pilot Hood

Pilot

Bracket

CO105a

Fig. 68 Remove pilot hood.

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00 djt

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 69 Remove pilot orifice.

ST350

Jefferson

air shutter adj

3/20/00 djt

Pilot

ST916

Fig. 67 Locate pilot.

CO142

Rf pilot Conversion

6/07 djt

Pilot Hood

Index

Marks

Pilot Bracket

CO143

Fig. 70 Remove pilot hood. (Your pilot may have a different
appearance.)

FP1037b

comfort valve

convert

3/6/01 djt

LOCAL

REMOTE

O

N

PILO

T

OFF

LED

Motor Top Cap

Center

Plunger

Blue - NG

Red - LP

FP1037b

Fig. 66 Depress and turn center plunger.

Valve

4. Insure manifold pressure remains between 3.2” - 3.5”

w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the
manifold pressure, for NG, using a Torx #10 key turn
the blue screw clockwise to increase the manifold
pressure. Turn the screw counterclockwise to de-
crease the pressure. Use the red screw to adjust LP.

5. Replace motor top cap.
Pilot Orifice Conversion
1. Locate pilot. (Fig. 67)

2. Replace pilot orifice.
Pilot Type 1 (SIT Pilot)

Remove pilot hood by lifting up. (Fig. 68) Do not

remove the snap ring to remove the pilot hood.
NOTE: It is not necessary to remove the pilot tube
for conversion.

Remove pilot orifice with Allen wrench. (Fig. 69)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with

index tab.

Pilot type 2 (Honeywell Pilot)

Loosen pilot hood turning counterclockwise using a

7/16” wrench. (Fig. 70) NOTE: You may use pen-
etrating oil to prevent pilot hood threads from seizing
up.

Remove pilot orifice with needlenose pliers. (Fig.

71) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.

Install the conversion orifice.

Reinstall pilot hood and tighten until mark on pilot

hood aligns with mark on pilot bracket.

Advertising
This manual is related to the following products: