Radiance direct vent gas heater, Wall centerline from floor, Hearth requirements – Vermont Casting RADVTCB User Manual

Page 7: Wall and ceiling clearances

Advertising
background image

7

Radiance Direct Vent Gas Heater

20012697

Parallel Installation:

Minimum Clearance and Flue Centerline

Fig. 3 Parallel installation, minimum back and side clear-
ances, and flue centerlines.

ST130

�����
������������
�����

42" (1070mm)

Min. Alcove Width

48"

(1220mm)

Max. Alcove

Depth

6"

(150mm)

6"

(150mm)

4" (102mm)

ST129

�����
������������
�����

18"

(457mm)

18"

(457mm)

6"

(150mm)

6"

(150mm)

��

��

Corner Installation:

Minimum Clearance and Flue Centerline

Fig. 4 Corner installation, minimum corner clearances and
flue centerline.

Wall Centerline from Floor

ST131b

Stardance

wall thimble

9/28/00 djt

A

A

Effective Minimum
Centerline

57” (1448 mm)

(CFM Corporation Pipe)

55” (1399 mm) (Simpson DuraVent Pipe)

ST131b

Fig. 5 Minimum wall centerline.

Direct Vent Only

Hearth Requirements

The Radiance Heater must be installed on rigid flooring.
When the heater is installed directly on any combustible
surface other than wood flooring, a metal or wood panel
extending the full width and depth of the unit must be
used as the hearth. There are no other hearth require-
ments.

* needed for installing DuraVent Minimum Vent Kit #2792 or
CFM Corporation Minimum Vent Kit #7TFSMSK.

A

C

D

ST101b

Stardance

Direct Vent

Min. Clrnc

9/28/00 djt

B

A: Rear Wall

4” (102 mm)

B: Min. Clearance

44” (1118 mm)*

C: Min. Alcove Height

72” (1830 mm)*

D: Max. Alcove Depth

48” (1220 mm)

Sidewall Clearance

6” (150 mm)

ST101b

Fig. 6 Dimensions and clearances to ceiling or alcove.

Direct Vent Only

Wall and Ceiling Clearances