Vermont Casting RADVTCB User Manual

Page 40

Advertising
background image

40

40

Radiance Direct Vent Gas Heater

20012697

Table 3. Air Shutter Adjustment

Natural Gas

Natural Gas

LP

Model

High Altitude

RADVT/RADVC

1/2” Open

1/2” Open

1/2” Open

Table 4. High Altitude Orifice

[Required for altitudes above 2000’ (610 m) up to 4500’ (1,370 m)]

Input (BTU/h)

Model

Orifice

Part #

Minimum Maximum

RADVT/RADVTC #33 / 0.113” 20012554

25,000 36,000

(Natural gas only)

Table 2. Injector Orifice Size Matrix

Conversion to Natural Gas

Input (BTU/h)

Model

Kit #

Orifice

Part #

Minimum Maximum

RADVT

20012899

RADVTC

20012902

#31 / 0.120” 20006927

25,000

38,000

Conversion to LP

Input (BTU/h)

Model

Kit #

Orifice

Part #

Minimum Maximum

RADVT

20012729

RADVTC

20012900

1.75 mm

20012946

25,000

36,000

*LP models do not need re-orificed up to 4500’ (1,370 m) above sea level.

5. Replace glass and stove front.
6. Restore gas to system and relight appliance accord-

ing to Lighting Instructions on Page 31.

7. Leak check the system using a gas leak detector

solution.

8. Relight the main burner in both the “HI” and “LO” po-

sitions to verify proper burner ignition and operation.

Conversion is complete.