Lamp, Projector user commands, Format – Canon SX 50 User Manual

Page 66: Parameter, Response, Description, Example, Commands supported, Environment

Advertising
background image

Projector User Commands


- 60 -

Revision History / Date

Changes

Revised by

Approved by

LAMP

Lamp output setting

Format

LAMP=<Lamp output setting parameters:ID>

Parameter

<Lamp output setting parameters:ID>

NORMAL Normal
SILENT Silent

cooling

The parameters which can be set at any given point in time can be obtained using the RANGE
command. For details, refer to the RANGE command.

Response

"i:OK" is returned if the parameter was set properly.
For details on other responses, refer to the "Error List".

Description

This command is used to set the light quantity of the lamp to "NORMAL" or "SILENT" (reduced light quantity
appropriate for silent cooling).

(1) For models other than SX7 Mark II: It can be executed when the projector is in both the remote mode and

power-on status at the same time.
For SX7 Mark II: It can be executed whenever the projector is in the power-on status.

(2) A “busy” response is given while the zoom or focus lens is being driven.

(Refer to the ZCONTDRV command and FCONTDRV command.)

(3) This command is the same as the menu functions in the table below.

Model

Menu

SX50

[Image adjustments] - [Lamp mode setting]

SX6, SX60, X600, SX7, X700,
SX7 Mark II

[Image adjustments] - [Lamp mode setting]

(4) The GET command can be used to retrieve the current lamp output.

For details, refer to the GET command.

Example

Setting

> LAMP=NORMAL

The lamp output is set to “NORMAL”.

< i:OK

Reference

> GET LAMP or ?LAMP

This retrieves the lamp output.

< g:LAMP=SILENT

Acquisition of parameters which can be set

> RANGE LAMP

< r:LAMP=I, NORMAL, SILENT "NORMAL" or "SILENT" can be set for the lamp output.

* Commands are indicated by ">", and responses are indicated by "<".

Commands supported

This defines the environments that support the command (power supply state, input signal state).

SX50

01.00**

SX6

01.01**

SX60

01.01**

X600

01.01**

SX7

01.01**

X700

01.01**

SX7 Mark II

01.02**

O O O O O O O

Environment

This defines the environments that support the command (power supply state, input signal state).

Power

Input

Mode

Model

OFF ON PM

D-RGB A-RGB1 A-RGB2 COMP

Video S-Video D-Video SCART None Remote Local

Remarks

SX50 x

O

x O O

O

O O

O

- - O O x

SX6, SX60,

X600

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7, X700

x

O

x

O

O

O

O

O

O

O

O

O

O

x

SX7 Mark II x

O

x

O

O

O

O

O

O

O

O

O

O

O

* If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response.
* When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

Setting

Advertising