Iii. specifications – Galaxy Audio CHECK MATE CM-140 User Manual

Page 4

Advertising
background image

III. Specifications

Standard Applied: IEC651 Type2, ANSI S1.4 Type2.

Frequency Range: 31.5Hz to 8KHz

Measuring Level Range: 32dB to 130dB

Frequency Weighting: A / C

Microphone: 1/2-inch electret condenser microphone

Display: LCD

Digital Display: 4 digit

Resolution: 0.1dB

Display Update: 0.5 sec.

Time Weighting: FAST (125mS), SLOW (1 sec.)

Level Ranges: Lo: 32 dB to 80 dB

Med: 50 dB to 100 dB

Hi: 80 dB to 130 dB

Accuracy:
±1.5dB ( under reference conditions, 94dB@1kHz )

Dynamic Range: 50 dB

Alarm Function: “

OVER” is when input is more than

upper limit of range.

UNDER” is when input is less than lower

limit of range.

MAX / MIN Hold:

Hold readings the Maximum and Minimum Value.

q

Display with 0.1dB steps on a 4-digit LCD.

q

Two equivalent weighted sound pressure levels, A and

C.

q

AC signal output is available from standard 3.5mm

coaxial socket suitable for a frequency analyzer, level
recorder, FFT analyzer, graphic recorder, etc.

2

CM-140 SPL METER

Advertising