Step 7 electrical requirements, Installation step 7, Electrical requirements – Chamberlain Security+ 3900PLD User Manual

Page 12

Advertising
background image

12

INSTALLATION STEP 7

Electrical Requirements

To avoid installation difficulties, do not run the
operator at this time.

To reduce the risk of electric shock, your operator has a
grounding type plug with a third grounding pin. This plug
will only fit into a grounding type outlet. If the plug doesn’t
fit into the outlet you have, contact a qualified electrician to
install the proper outlet.

If permanent wiring is required by your local code,
refer to the following procedure.

To make a permanent connection through the 7/8" hole in
the back of the operator (according to local code):

Remove the operator from the torsion bar, remove cover

screws and set the cover aside.

Remove the attached green ground terminal.

Cut black and white wires and strip away 1/2" (1.3 cm)

of insulation, 3" (7.6 cm) before spade terminals.

Remove the power cord from unit.

Install a 90

o

conduit or flex cable adapter to the 7/8"

hole. Reinstall operator to torsion bar.

Run wires through conduit, cut to proper length and

strip insulation.

Attach with wire nuts provided.

Properly secure wire under plastic ties so that wire does

not come in contact with moving parts.

Reinstall the cover.

To avoid installation difficulties, do not run the
operator at this time.

RIGHT

WRONG

Black Wire
From Power Cord

White Wire
From Power Cord

Ground Tab

Green
Ground
Screw

Ground Wire

Flexible Conduit

PERMANENT WIRING CONNECTION

90˚ Connector

Green Wire

White Wire

Black Wire

PERMANENT WIRING CONNECTION

To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Be sure power is not connected to the operator, and

disconnect power to circuit BEFORE removing cover to
establish permanent wiring connection.

• Door installation and wiring MUST be in compliance with

ALL local electrical and building codes.

• NEVER use an extension cord, 2-wire adapter or change plug

in ANY way to make it fit outlet. Be sure the operator is
grounded.