Having a Problem? (Continued)

12. The operator won't operate due to power failure:

•

Use the emergency release handle to disconnect the

door. The door can be opened and closed manually.
When power is restored, pull manual release a
second time.

•

If a Standby Power Unit is connected, the operator

should be able to operate up to 20 times without
power.

13. Door loses limits.

•

Collar not tightened securely. Tighten collar

(see Assembly Steps 1 and 2) and reprogram limits
(see Adjustment Step 1).

14. The operator moves when the door is in operation:

•

Some minor movement is normal for this product. If it

is excessive the collar will wear prematurely.

•

Check to make sure the torsion bar is not moving

left/right excessively.

•

Check to make sure the torsion bar is not visibly

moving up and down as it rotates.

•

Check that the operator is mounted at a right angle

to the jackshaft. If not, move the position of the
mounting bracket.