Step 2 attach the emergency release ropeand handle, Step 3 install power door lock(not provided), Installation step 2 – Chamberlain Security+ 3900PLD User Manual

Page 8: Installation step 3, Attach the emergency release rope and handle, Install power door lock (not provided)

Advertising
background image

NOT

ICE

Overhand
Knot

Emergency
Release Handle

Overhand
Knot

Rope

Motor Unit

Emergency
Release Cable

To prevent possible SERIOUS INJURY or DEATH from a falling
door:
• If possible, use emergency release handle to disengage door

ONLY when door is CLOSED. Weak or broken springs or
unbalanced door could result in an open door falling rapidly
and/or unexpectedly.

• NEVER use emergency release handle unless doorway is

clear of persons and obstructions.

INSTALLATION STEP 2

Attach the Emergency Release Rope
and Handle

Thread one end of the rope through the hole in the top

of the red handle so “NOTICE” reads right side up as
shown. Secure with an overhand knot at least 1"
(2.5 cm) from the end of the rope to prevent slipping.

Thread the other end of the rope through the loop in the

emergency release cable.

Adjust rope length so the handle is no higher than 6'

(1.83 m) above the floor. Secure with an overhand knot.

NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.

8

Staples

Lock Screw
1/4-20 x 1/2" (2)

HARDWARE SHOWN ACTUAL SIZE

INSTALLATION STEP 3

Install Power Door Lock
(Not Provided)

The lock is used to prevent the door from being
manually opened once the door is fully closed.

1. Select a door roller to mount the lock above. Check

for clearance. If possible select a roller on the same
side of the door as the motor unit.
The second roller up from the bottom is ideal in
most installations.

2. Ensure rail surface is clean and adhere lock

template to achieve a 3" (7.6 cm) distance between
the center of the roller and the pin hole (Figure 1).

3. Drill holes as marked on the template.
4. Fasten power door lock to the outside of the garage

door track with hardware provided.

5. Run bell wire up wall to motor unit. Use insulated

staples to secure wire in several places.

6. Plug connector into the motor unit (Figure 2).
NOTE: Lock must be mounted within 10' of the
power head.

Lock Template

Roller

Garage
Door Track

TOP

DRILL 5

/16"

DRILL

3/4"

DRILL 5

/16"

132A2505

Approx. 3"
(7.6 cm)

TOP

DRIL

L 5/1

6"

DRIL

L 3/4

"

DRIL

L 5/1

6"

132A2505

Door Track

Figure 2

Figure 1

Advertising