Settings

Cam Input Settings

•

Edge - Selects if the signal triggers off the falling or rising edge. Changing edges will require a reset.

•

Cam Trigger Angle - The angle between TDC and when the intake cam is at its most retarded
position.

•

RPM Filter Start - The RPM at which the software filtering done by the ECU begins.

•

Min Angle - When the software filtering starts any angle that the ECU sees below this value is
considered erroneous.

•

Max Angle - When the software filtering starts any angle that the ECU sees above this value is
considered erroneous.

Cam Output Settings

•

VCT Frequency - Frequency at which the variable cam timing solenoid runs at.

•

Steady Cam Pos DC - This value is the duty cycle that will keep the cam in a fixed position. Will be
somewhere around the 50% point. This value is best set when the engine is up at operating
temperatures.

•

Min Duty - The minimum duty the controller will output to the VCT solenoid. Generally 10% less
then the ‘Steady Cam Pos DC’. I.e. if the ‘Steady Cam Pos DC’ is equal to 45% then the ‘Min Duty’
will equal 35%.

•

Max Duty - The maximum duty the controller will output to the VCT solenoid. Generally 10% more
then the ‘Steady Cam Pos DC’. I.e. if the ‘Steady Cam Pos DC’ is equal to 45% then the ‘Max Duty’
will equal 55%.

•

Deadband - Area around the target cam angle which the controller stops controlling. E.g. target cam
angle = 10deg, deadband = 1deg, therefore if the cam angle falls between 9deg and 11deg then the
variable cam controller will ignore any changes in cam angle and considered it to be controlled.

•

Min Coolant Temp - The minimum coolant temp that the variable cam timing controller will work.
Below this the output duty cycle will be zero.

•

Max RPM - The maximum RPM that the variable cam timing controller will work. Above this RPM
the output duty cycle will always be zero.

•

Max Cam Angle - Any value in the ‘VCT Cam Angle Map’ that goes above this will be clamped by
the output to this value.

Default Settings

Cam Input Settings:

•

Edge Vehicle Dependent

•

Trigger Angle Vehicle Dependent

•

RPM Filter Start

3000

RPM

Page: 112