Trigger setup – Haltech E8 User Manual
Page 30

Haltech E11/E8 Instruction Manual
The Trigger and Ignition setup pages are the most Important part of any Installation!.
Getting these settings wrong or not understanding them will lead you into problems. The ECU has no idea
what is connected to it or what it supposed to see. This is why the settings must be properly set to suit the
application. The other issue is making sure the ECU can interface to the sensor(s) which different types of
signals like Hall Effect signals and Reluctor (Magnetic sensor). Interfacing to these signals may require
the use of external signal conditioners such as the Haltech RA10.
Trigger Setup
Figure 27 - Trigger Setup Screen
Trigger Group
•
Type of Trigger System -
Select the type of trigger that your engine uses from the options in the
drop down menu.
Page: 30
Copyright © Haltech 2008