Haltech F9A User Manual

Page 34

Advertising
background image


33

Aux. In/Out Function: The Auxiliary Input/Output on the F9 can be configured for one of

several functions. Most of these functions relate to the configuration of the system.
The available functions are:

Disabled

No effect on ECU operation.

Staging Signal

Output - Logic output that indicates Staging

conditions. If Staging is selected, and the
Staged injector are firing, this signal will be
high (5 volts), otherwise it will be low (~ 0
volts).

TCC Input

Input - This input is used in conjunction with the

TCC Optional Output. [16.4]

Turbo Timer

Input - This input is used in conjunction with the

Turbo Timer Optional Output. [16.12]


Since the Auxiliary Input/Output line can only perform one duty, all of the above

functions are mutually exclusive. i.e. although two programmable outputs exist on the
F9, only one of the TCC and Turbo Timer functions may be chosen. Keep this
function in mind when deciding on the F9 configuration you wish to run.

Advertising
This manual is related to the following products:

F9