E.4 Trigger Gain and Reluctor Adaptor Tuning


Motronic Filter

The Motronic Filter setting defines the level of filtering used to correct the signal provided by
sensors when the trigger wheel has missing teeth, such as Motronic. In the E6X this value
should be set to 0 if standard reluctor wheel is used, and approx 2 when a missing tooth wheel
is used. This value can be changed to suit individual applications and can also be used to
condition any reluctor signal if required. The scope traces below show the effect of the
Motronic filter settings on the signal prior to the gain circuit. The signal used is a Motronic
60-2.

Motronic signal with Motronic Filter = 0

Motronic signal with Motronic Filter = 1