Troubleshooting, Performance is bad, Per port led is lit, but the traffic is irregular – Interlogix MC350-1T-2S User Manual

Page 26

Advertising
background image

26

4. Troubleshooting

This chapter contains information to help you solve issues. If the Industrial Gigabit Media Converter is not functioning

properly, make sure the Industrial Gigabit Media Converter is set up according to instructions in this manual.

The per port LED is not lit

Solution:

Check the cable connection of the Industrial Gigabit Media Converter.

Performance is bad

Solution:

Check the speed duplex mode of the partner device. The Industrial Gigabit Media Converter is run at Auto-negotiation

mode and if the partner is set to half duplex, then the performance will be poor.

Per port LED is lit, but the traffic is irregular

Solution:

Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to

change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.

Why the Industrial Gigabit Media Converter doesn’t connect to the network

Solution:

Check per port LED on the Industrial Gigabit Media Converter. Make sure the cable is installed properly. Make sure

the cable is the right type. Turn off the power. After a while, turn on power again.

Can I install S3X-S2X or other non wide temperature SFP module into SFP slot of Industrial Gigabit

Media Converter?

Solution:

Yes, you can. However, non wide temperature SFP module cannot operate under -40 to 75 degrees C.

Advertising