27

5. Cable Connection Parameters

The wiring details are as below:

100FX Fiber Optical Cables:

Standard

Fiber Type

Cable Specification

100Base-FX

(1300nm)

Multi-mode 50/125μm or 62.5/125μm

Multi-mode 50/125μm or 62.5/125μm

100Base-FX

(1310nm)

Single-mode 9/125μm

100Base-BX-U

(TX :1310/RX :1550)

100Base-BX-D

(TX :1550/RX :1310)

Single-mode 9/125μm

1000X Fiber Optical Cables:

Standard

Fiber Type

Cable Specification

1000Base-SX
(850nm)

Multi-mode 50/125μm or 62.5/125μm

Multi-mode 50/125μm or 62.5/125μm

1000Base-LX
(1300nm)

Single-mode 9/125μm

Wiring Distances:

Standard

Fiber

Diameter (micron) Modal Bandwidth (MHz *

km)

Max. Distance (meters)

1000Base-
SX

MM 62.5

62.5
50
50

100
200
400
500

220
275
500
550

MM 62.5

50
50

5
4
5

550

1000Base-
LX

SM 9

N/A

5000*

#

Notice

The Single-mode port (1000Base-LX port) of MC350-1T-2S complies with LX 5
kilometers and provides additional margin allowing for a 10/20/40/50/60 kilometer
Gigabit Ethernet link on single mode fiber.