Interlogix NS3702-24P-4S User Manual User Manual
Page 132

132
VLAN 3 : Port-4, Port-5 and Port-6
VLAN 1 : All other ports – Port-7~Port-48
Figure 4-6-14:
Changes Port VLAN of Port 1~3 to be VLAN2 and Port VLAN of Port 4~6 to be VLAN3
For the VLAN ports connecting to the hosts, please refer to 4.6.10.1 examples. The following steps will focus on the VLAN Trunk
port
configuration.
1. Specify
Port-7
to be the 802.1Q VLAN Trunk port.
2. Assign
Port-7
to both VLAN 2 and VLAN 3 at the VLAN Member configuration Page.
3. Define
a
VLAN 1
as a “Public Area” that overlapping with both VLAN 2 members and VLAN 3 members.
4. Assign the VLAN Trunk Port to be the member of each VLAN – which wants to be aggregated. For this example, add Port-7 to
be VLAN 2 and VLAN 3 member port.
5. Specify
Port-7
to be the 802.1Q VLAN Trunk port, and the Trunking port must be a Tagged port while egress. The Port-7
configuration is shown in
Figure 4-6-15.