Interlogix NS3702-24P-4S User Manual User Manual
Page 362

362
Reboot & Alarm:
It means system will reset the PoE port and issue an
alarm message via Syslog, SMTP.
Alarm:
It means system will issue an alarm message via Syslog, SMTP.
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time, due to there are so
many kind of PoE device on the market and theyhave different rebooting time. The
PD Alive-check is not a defining standard, so the PoE device on the market doesn’t
report reboots done information to NS3702 PoE Switch, so user has to make sure
how long the PD will be finished to boot, and then set the time value to this column.
System is going to check the PD again according to the reboot time. If ou can not
make sure precisely booting time, we suggest you to set it longer.
Buttons
: Click to apply changes
: Click it to reset configuration which has not been saved yet.