Interlogix 2315 Series User Manual

2315 series, Panel door magnetic contact, Installation instructions

Advertising
background image

2315 Series

Panel Door Magnetic Contact

Models: 2315A, 2317A

Installation Instructions

Mounting

Caution:

Locate the magnet away from manual

handles and latches to prevent it from being used
as a foothold or handle to close the door.

1. Slide the slot of the switch over the beveled-edge of

the L-bracket and snap it tightly into place as shown in
Figure 1. Screw down firmly.

Figure 4

2. Align the magnet with the switch and use screws to

attach it to the door as shown in Figure 2. The switch
and magnet must be aligned within 1/2 inch of each
other to prevent false alarms.

3. Connect the switch wires to the alarm system and test to

verify proper operation.

Important:

The contact should be mounted at

least 13 inches from the floor. If other track-
mounted devices interfere, mount the switch under
them.

Figure 1

Figure 2

Optional:

Use the existing roller-track bolts to

mount the switch without using the L-Bracket as
shown in Figure 3.

Figure 3

The magnet can be attached at
two different elevations from
the door.

Fits standard 2” roller-tracks for
sectional/panel overhead
doors.

elevation 1

elevation 2

1/4 to 1/2”

spacing

Advertising