2700 Series Installation Instructions

Installation

These are the installation instructions for models 2706AP,

2706AS, 2707A, and 2707AD.

2707A/2707AD: Position magnet and switch so that the labels

read in the same direction and the Sentrol S on the magnet

aligns directly with the S on the switch. The set-up gap

distance is .4" (3/8") (1.02 cm). Switches will operate at

approximately .2" (.5 cm) to .6" (1.52 cm) on closing and go

into alarm at approximately .4" (1.02 cm) to .8" (2.03 cm) on

opening. Minimum gap is .2" (.5 cm). However, environmental

conditions, such as thickness of the metal to which the switch

and magnet attach, may alter gap distance. Therefore, we

recommend the following installation method:

1. Bring the magnet toward the switch until an ohmmeter

connected to the closed loop wires reads 0 ohms. Mark
this point.

2. Now bring the magnet closer to the switch until the meter

reads infinity. Mark this point.

3. Position the magnet midpoint between the two marks.

4. Use the magnet template to mark the mounting holes.

5. Pre-drill the mounting holes.

6. If a Pry Tamper plate is required, install it under the switch

with two #6 x 3/4" flathead screws. Connect the gold and

blue painted leads to the 24-hour circuit. The pry temper

plate is required for the Certified Safe and Vault

applications.

7. If the pry tamper is not used, discard the tamper plate and

mount the switch directly to the surface. Be sure to
connect the gold and green painted leads to the 24-hour
circuit.

2706AP/2706AS: Follow steps 1 through 7 as outlined for

models 2707A/2707AD. The 2706AP/2706AS has a built-in

remote test feature which you may order either on the

protective or supervised loop. To perform remote test

operation, apply 12 V DC, 5 mA max. current, to the green

(remote test) wires. 24 V DC remote test is available on

request.

With magnet positioned correctly, the switches will trip if an

external magnet (67 gauss or greater) is used in an attempt to

defeat the switch.

Ordering information

Part #

Loop type

Electrical
configuration

Gap distance
(Make)*

2706AS

Open or closed

SPDT

0.2" to 0.6"

2706AP

Open or closed

SPDT

0.2" to 0.6"

2707A

Open or closed

SPDT

0.2" to 0.6"

2707AD

Open or closed

DPDT

0.2" to 0.6"

Lead Type for all models: 3' Stainless steel armored cable

*Gap distances are nominal make distance ±20%.

Form C (2747A)

Voltage: 30 V AC

Current: .25 A Max.

Power: 3.0 W Max.

P/N 11247 • REV E • 21SEP11