Product Summary

Each SuperBus

®

2000 8-Zone Input Module adds eight

supervised hardwire zones. Each module includes mounting
hardware and eight 2.0K ohm end-of-line (EOL) resistors.
Power for the module is provided by the panel.

Both normally open and normally closed detectors can be
wired to module inputs. Using an EOL resistor on each loop
input, the module monitors all zones and alerts the panel if
there is an open/short circuit.

Advent

®

panels can support multiple modules for up to 250

zone inputs. UltraGard

®

panels can support up to eight

modules for 64 additional zone inputs. Concord

panels can

be expanded up to 76 zone inputs.

For additional security, the plastic case includes space for
installing a magnet and reed switch that can provide tamper
protection to detect cover removal.

SuperBus 2000

vs. SuperBus

SuperBus 2000 panels have the ability to auto-address mod-
ule unit numbers. When the panel is powered up, the panel
automatically reads the unique SuperBus 2000 device ID
number and assigns a unit number to the module. This elim-
inates manually setting DIP switches and the chance of
identical unit number conflicts.

SuperBus 2000 Panels
R Advent
R Concord (software versions 2.0 and later)
SuperBus panels communicate with SuperBus 2000 mod-
ules but require the module unit number to first be set man-
ually with DIP switches.

SuperBus Panels
R UltraGard
R Concord (software versions 1.0–1.6)

Module Components

Figure 1.

Module Circuit Board Components

Table 1. Module Component Descriptions

Component

Function

Unit Number DIP
Switches

Used for manually setting unit
numbers (SuperBus panels).

SuperBus 2000
Device ID Number
Label

Identifies unique device ID
number (SuperBus 2000
panels).

Software Version
Label

Identifies the installed
software version.

Green POWER
LED

Indicates module power status.

Red BUS LED

Flashes to indicate normal
communication to the panel
bus.

Wiring Terminals

Used for power, bus, and
hardwire zone input
connections.

SOFTWARE
VERSION LABEL

GREEN POWER
LED

UNIT NUMBER
DIP SWITCHES

WIRING
TERMINALS

9712G01A.DSF

RED BUS
STATUS LED

SUPERBUS 2000
DEVICE ID
NUMBER LABEL

8557109A.DS4

Advertising