Wiring the Module

Wiring the Module

To Wire the Module to a Panel

“«œÀÌ>˜Ìt

On Advent panels, the BUS 1 and BUS 2 headers
must be used only for fire or burglary applications. Do
not mix fire and burglary bus devices on either header.

1.

Make sure the panel AC power is turned off or
removed, and the panel backup battery(s) are
disconnected.

2.

Wire the module to the panel as shown in Figure 7 and
explained in Table 4.

Figure 7.

General Module Wiring

* Panel SuperBus device connector wiring harness.
(Connect to either panel connector.)

To Wire Detectors to the Module

Follow the maximum zone input wire length (run)
guidelines in Table 5 based on the type of wire used.

“«œÀÌ>˜Ìt

For Advent UL-864 Listed Installations, all inputs must
be dedicated to either fire or burglary applications. Do
not mix fire and burglary on

any module in any

partition for these installations.

1.

Figure 8 shows an example of how to connect up to
eight normally closed (N/C) or normally open (N/O)
intrusion circuits to the module.

Figure 8.

Connecting N/C and N/O Intrusion Circuits
to the Module

Table 4. SuperBus Module/Panel Wiring

Module

Terminals

Advent*

Ultra-

Gard

Concord

13
(+12VDC)

Red

12 4

14 (BUS A)

Green

13

5

15 (BUS B)

White

14

6

16 (GND)

Black

15

3

9712G03A.DSF

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ZONE COM

M

ON

ZO
NE 1

ZO
NE 2

+12

VDC (

R

ED)

BUS A (

G

RN)

BUS B (

W

HT)

GND (

B

L

K

)

TO PANEL

SUPERBUS TERMINALS

OR CONNECTOR

(SEE TABLE)

TO ZONE

INPUT

DEVICE

(SHARED COMMONS)

ZO
NE 3

ZO
NE 4

ZO
NE 5

ZONE COM

M

ON

ZONE COM

M

ON

ZO
NE 6

ZO
NE 7

ZONE COM

M

ON

ZO
NE 8

Table 5. Zone Input Wire Runs

Gauge

Max. Wire Run*

18

750 Feet

22

300 Feet

*Wire run based on 10 ohms maximum wire and
device resistance including 2.0K ohm EOL resistor.

9712G04A.DSF

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

ZO
NE 1

ZONE COM

UL-LISTED

NORMALLY

OPEN

(N/O)

CONTACTS

IN PARALLEL

2.0K OHM EOL RESISTOR 49-467

(INSTALL AT LAST DEVICE)

UL-LISTED

NORMALLY

CLOSED

(N/C)

CONTACTS

IN SERIES

< OR >