Programming and Testing

Programming and Testing

Refer to the specific panel Installation Instructions for add-
ing (learning) hardwire sensors into panel memory and test-
ing sensors.

If the UltraGard or Concord

system uses hardwire sensors

only, turn off the Receiver Failure feature in the panel.
Refer to the panel Installation Instructions for details.

Troubleshooting

Table 6 describes what to do if the module does not work
correctly.

Specifications

Compatibility:

Advent, Concord, UltraGard

Power Requirements:

12 VDC nominal, 35 mA maximum
(from panel)

Panel Data Bus:

ITI SuperBus and SuperBus 2000
digital data bus

Inputs:

Eight supervised, hardwire zones

Storage

Temperature: -30° to 140° F (-34° to 60° C)

Operating Temperature: 32° to 120° F (0° to 49° C), up to

140° F (60° C) under temporary
conditions

Maximum Humidity:

90% relative humidity, non-condens-
ing

Dimensions:

5.25" x 4.125" x 1.0" (LxWxD)

Color:

Belgian gray

Case Material:

ABS plastic

Installation:

On wall or in panel cabinet
mounting

Listings:

UL 365 Police Station Connected
Burglar Alarm Units and Systems

UL 609 Local Burglar Alarm Units
and Systems

UL 864 Control Units for Fire
Protective Signaling Devices

UL 985 Household Fire Warning
System Units

UL 1023 Household Burglar Alarm
System Units

UL 1610 Central Station Burglar
Alarm Units (Commercial Burglary)

UL 1637 Home Health Care Signal-
ing Equipment

CSFM California State Fire Marshall
(applied for)

FM Factory Mutual (applied for)

MEA New York City Material
Equipment Acceptance (applied for)

DOD Sensitive Compartment
Information Fac. (applied for)

ULC Canada Commercial
Fire/Burglary Warning (applied for)

œÌi

See specific panel

Installation Instructions for

complete UL installation requirements for the system
you are installing.

Table 6. Troubleshooting

Problem

Action/Solution

The green POWER
LED stays off.

1.

Check for incorrect wiring
connections.

2.

Make sure panel AC power is
applied and the backup
battery(s) are connected.

3.

If the LED still remains off,
replace the module.

The red BUS LED
doesn’t flash to
indicate
communication
with the panel.

1.

Verify that the panel recog-
nizes the module by entering
program mode (see specific
panel Installation Instruc-
tions
).

2.

Check for incorrect wiring
connections.

3.

For Concord (software ver-
sions 1.0–1.6) and UltraGard
panels make sure that mod-
ule DIP switch 1 is set to
“M.” For Concord (software
versions 2.0 or later) and
Advent panels make sure that
module DIP switch 1 is set to
“A.”

4.

If the LED still doesn’t flash,
replace the module.

The red BUS LED
stays lit and blinks
when zones are
tripped, but the
system does not
respond.

1.

For Concord (software ver-
sions 1.0–1.6) or UltraGard
systems, check for bus
devices with the same unit
number setting.

2.

Re-initialize the panel by dis-
connecting and reconnecting
panel power.

3.

Make sure the zone has been
“learned” into panel memory.

4.

Verify that the panel recog-
nizes the module by entering
program mode (see specific
panel Installation Instruc-
tions
).

5.

Remove zones and try install-
ing the module without the
zones.

6.

Replace the module.