Power Up and Bus Communication

Power Up and
Bus Communication

On Concord and Advent Panels

This section describes how to power up the panel and mod-
ule for both new and existing installations.

New Installations

1.

Verify that all wiring between the panel and module is
correct.

2.

Connect the panel backup battery(s) and restore panel
AC power. Alphanumeric touchpad displays should
come on.

3.

Both the green and red LEDs will turn on for one sec-
ond. The green POWER LED will remain on and the
red BUS LED should flash to indicate successful com-
munication with the panel.

œÌi

If the green POWER LED is not on or the red BUS
LED does not flash, remove AC panel power, discon-
nect the backup battery(s), and see Table 6 “Trouble-
shooting.”

Existing Installations

Concord Panels– Same as new installation.

Advent Panels–

1.

Verify that all wiring between the panel and module is
correct.

2.

Connect the panel backup battery(s) and restore panel
AC power. Alphanumeric touchpad displays should
come on.

3.

Press 8 for System Menu.

4.

Press 0 for Program Menu.

5.

Enter your Install Code (default 0123).

6.

Enter Item Number 48001 to add SuperBus devices.
All installed devices are automatically added (learned)
into panel memory when Devices Added is indicated.

7.

Press * twice to return to the Main Menu.

8.

Both the green and red LEDs turn on for one second.
The green POWER LED will remain on and the red
BUS LED should flash to indicate successful commu-
nication with the panel.

œÌi

If the green POWER LED is not on or the red BUS
LED does not flash, remove AC panel power, discon-
nect the backup battery(s), and see Table 6 “Trouble-
shooting.”

On UltraGard Panels

1.

Verify that all wiring between the panel and module is
correct.

2.

Verify nonconflicting bus device unit number settings.

3.

Connect the panel backup battery and restore panel AC
power.

4.

Turn on the panel AC power.

5.

Set the UltraGard panel RUN/PROGRAM switch to
PROGRAM.

If the alphanumeric touchpad displays 1-OFF and the 1
is flashing, you must enter the 4-digit installer code to
place the panel into program mode.

Alphanumeric touchpads should display PROGRAM
MODE
and the red BUS LED on the module should be
flashing continuously, indicating successful communi-
cation with the panel.

œÌi

If the green POWER LED is not on or the red BUS
LED does not flash, set the RUN/PROGRAM switch
(UltraGard) to RUN, remove AC panel power, discon-
nect the backup battery, and see Table 6 “Trouble-
shooting.”