User interface, Unit configuration, Remote control configuration – Carrier 40QNQ User Manual

Page 17: Wired control

Advertising
background image

17

A

Wall

Hanging

B racket

Hook

Hole

R etainer

C lip

R etainer

C lip

B

UNIT SIZE

DIMENSION

A

B

40QNC01824

13.4

10.6

40QNC030

12.2

12.2

40QNC036

12.2

12.2

40QNQ018

13.4

10.6

40QNQ024

13.4

10.6

40QNQ030

12.2

12.2

40QNQ036

12.2

12.2

A08365

Fig. 29 -- Wall Mounting Details

8. If the refrigerant piping connections are located outside the

wall, tighten the flare connections as shown in Fig. 30. Insu-
late all exposed refrigerant lines and secure to the wall and

fill any void spaces in the hole.

Adjustable wrench or torque wrench

Outdoor end
Indoor end

3

1

2

A07201

Fig. 30 -- Tightening Connections

USER INTERFACE

The indoor unit includes a wireless remote control to operate the
unit (an Owner’s Manual is supplied with the unit). If you have

two units installed in the same space and they need to work

independently, the remote controls and the units need to be
configured as follow:

Unit Configuration

Turn the unit off by pressing the

. Press and hold the

and

buttons of the remote control for more than 5 seconds. The

display will be cleared and the time segments will display the first
configuration item (rAdr=remote address) and the temperature

segments will display the default value of this configuration item
(Ab=control of both indoor units). Press

and

to change the

default value to the new value of (a) or (b). Press the

button to

transmit the new configuration to the unit. Press the

button to

leave the configuration menu.

Remote Control Configuration

Turn the unit off by pressing the

button. Press and hold the

and

buttons for more than 5 seconds. The display will be

cleared and the time segments will display the first configuration

item (CH=remote address) and the temperature segments will

display the default value of this configuration item (Ab=control of
both indoor units).

Press

and

to change the default value to the new value of (a)

or (b). Press the

button to transmit the new configuration to the

unit. Press the

button to leave the configuration menu.

NOTE: When 30 seconds have elapsed and no buttons have been

pressed, the remote control will automatically exit the

configuration menu and resume its normal operation.
A wall mounted control or zone manager can be used to control a

unit or multiple units.

Wired Control

If a wall mounted wired control is required the following steps
should be performed at the same time the indoor control and power

wiring are being connected:

1. Unplug the connector on J5.
2. Remove the wire harness from the wired control box
3. Plug one end of the wire harness into the J5 connector on

the board

4. Route the other end of the wire harness to the back of the

unit along the low voltage wiring

5. Connect the other end of the wire harness to the field sup-

plied wiring between the indoor unit and the wired control

as shown in wired control installation instructions and Fig.
31.